How negative pressure is created
The containment is sealed off so that it is dust-tight. Negative pressure units extract air from the area, clean it through HEPA filters and discharge it outside. Fresh air flows in through defined inlet openings.
Because more air is extracted than can flow in through the openings, the pressure inside the containment is lower than outside. Air therefore flows inwards at every leak and through the decontamination units. At the same time, the air exchange dilutes the fibre concentration in the work area.
The same principle is used for other hazardous-material remediation, for example PCB, PAH, man-made mineral fibres or mould, when the risk assessment calls for an enclosure.
How negative pressure is measured
What is measured is the pressure difference between the containment and its surroundings. One measuring hose leads into the containment, the second port of the instrument sits in the adjacent room or outdoors.
The decontamination units are kept under negative pressure as well, so that air flows from outside through the units into the work area. Where there are several sections or units, pressure is measured at several points.
Recording as evidence
Many national rules require negative pressure to be measured and recorded continuously during the work. The record shows the client, the consultant and the authority that the protective measure was maintained, and when and for how long the pressure dropped.
Whether recording is required, how long the records are kept and who may inspect them is set by the national rules.
What happens when pressure drops
If negative pressure drops, the instrument triggers a visual or audible alarm. Work stops until the cause is fixed. Outside working hours, a person designated in advance takes care of this.
Possible causes include a failed negative pressure unit, a power cut, a clogged filter or a damaged enclosure.
Depending on the risk assessment, a standby unit or an emergency power supply for the extractors may be needed.