Negative pressure in the containment: rules, measurement and alarms

When friable asbestos is removed, the work area is sealed off and kept under negative pressure. Air then only flows inwards through leaks, and fibres do not escape into the surroundings. This page explains how negative pressure is created, measured and monitored, and links to the official rules of 18 European countries.

How negative pressure is created

The containment is sealed off so that it is dust-tight. Negative pressure units extract air from the area, clean it through HEPA filters and discharge it outside. Fresh air flows in through defined inlet openings.

Because more air is extracted than can flow in through the openings, the pressure inside the containment is lower than outside. Air therefore flows inwards at every leak and through the decontamination units. At the same time, the air exchange dilutes the fibre concentration in the work area.

The same principle is used for other hazardous-material remediation, for example PCB, PAH, man-made mineral fibres or mould, when the risk assessment calls for an enclosure.

How negative pressure is measured

What is measured is the pressure difference between the containment and its surroundings. One measuring hose leads into the containment, the second port of the instrument sits in the adjacent room or outdoors.

The decontamination units are kept under negative pressure as well, so that air flows from outside through the units into the work area. Where there are several sections or units, pressure is measured at several points.

Recording as evidence

Many national rules require negative pressure to be measured and recorded continuously during the work. The record shows the client, the consultant and the authority that the protective measure was maintained, and when and for how long the pressure dropped.

Whether recording is required, how long the records are kept and who may inspect them is set by the national rules.

What happens when pressure drops

If negative pressure drops, the instrument triggers a visual or audible alarm. Work stops until the cause is fixed. Outside working hours, a person designated in advance takes care of this.

Possible causes include a failed negative pressure unit, a power cut, a clogged filter or a damaged enclosure.

Depending on the risk assessment, a standby unit or an emergency power supply for the extractors may be needed.

Frequently asked questions

How much negative pressure does a containment need?
That depends on the country. Some rules set a minimum pressure difference in pascals, others require negative pressure without setting a value. The official texts are linked in the list of countries on this page.
Why is negative pressure measured continuously?
Negative pressure can drop at any time, for example when a unit fails, a filter clogs or the enclosure is damaged. A continuous record shows when this happened and for how long, and an alarm lets someone respond straight away.
Does negative pressure have to be recorded?
In many countries, yes. The record serves as evidence for the client, the consultant and the authority. Whether recording is required and how long the records are kept is set by the national rules.
Who has to respond to an alarm outside working hours?
A person designated in advance, who fixes the cause or has it fixed. For that person to know about it, the alarm has to be passed on beyond the site, for example by SMS or phone call.